Fix the section before aqueous staining
Ethanol fixation stabilizes cellular morphology; a brief rinse removes ethanol that would hinder hematoxylin uptake.
- STEP 1Fix in 70% ethanol30 sec
Before starting: Confirm frozen sections have been cut at 5–10 µm and mounted on positively-charged glass slides. Allow to air-dry at room temperature for ~30 seconds if the slide surface is very wet, then proceed immediately to Step 1. Do not allow sections to dry completely before fixation.
Place slide in Coplin jar containing 70% ethanol Start timer; immerse for exactly 30 seconds Remove slide at end of timer
WhyEthanol fixation rapidly precipitates proteins and stabilizes cellular morphology before aqueous staining. 70% concentration provides effective fixation while minimizing excessive tissue shrinkage compared to absolute ethanol.
- STEP 2Rinse in running tap waterdip, ~5 sec
Transfer slide to running tap water Dip briefly (~5 seconds) — a single pass is sufficient Do not over-rinse
WhyRemoves residual ethanol that would interfere with aqueous hematoxylin uptake. Brief dip prevents premature section hydration.